ELECTRONIC FUSES



Product ID (Click to see detail)
EGC (3AG) Fast Acting Glass Tube Fuses EGP (3AG) Fast Acting Glass Tube Fuses With Pig-Tail EDL (3AG) Slow Blow Glass Tube Fuses EDP (3AG) Slow Blow Glass Tube Fuses With Pig-Tail
EBC (3AB) Fast Acting Ceramic Tube Fuses EBP (3AB) Fast Acting Ceramic Tube Fuses With Pig-Tail MGC (2AG) Fast Acting Glass Tube Fuses MGP (2AG) Fast Acting Glass Tube Fuses With Pig-Tail
MDT (2AG) Slow Blow Glass Tube Fuses MDP (2AG) Slow Blow Glass Tube Fuses With Pig-Tail MBC (2AB) Fast Acting Ceramic Tube Fuses MBP (2AB) Fast Acting Ceramic Tube Fuses With Pig-Tail
LWR (Insulating Fuses) MCR (Microtron) Printed Circuit Board Fuses MDTU (51S) Slow Blow Glass Tube Fuses MDPU (52S) Slow Blow Glass Tube Fuses With Pig-Tail
EDLU (61S) Slow Blow Glass Tube Fuses EDPU (62S) Slow Blow Glass Tube Fuses With Pig-Tail EBCU (65NM) Fast Acting Ceramic Tube Fuses EBDU (65TS) Slow Blow Ceramic Tube Fuses
MGCV (50F) Quick Actinmg Low Breaking Capacity MDTV (50T) Time Delay Low Breaking Capacity MBCV (5OCF) Quick Acting High Breaking Capacity MBDV (50CT) Time Delay High Breaking Capacity



LWR : Insulating Fuses
  • Supply witn insulating P.V.C. tube
  • These fuses are designed for the protection of electric and electronic appliances
  • fuses ending are fully insulated and can be directly wired to circuits in confined areas without concern of electrical contact
  • Applicable for all Pig-Tail type fuses.
  • To Order, Add "LWR"
    e.g. - EGP(LWR), MGP(LWR)

  • Back To The Top


    MCR (Microtron): Printed Circuit Board Fuses
  • 3.1?x 7.5 mm
  • Ampere Rating: 0.063 to 7 A
  • Voltage Rating: 125 V and less
  • Electrical characteristics:
  • 100% - 240 Minutes, Minimum
  • 200% - 5 seconds, Maximum
  • Pig-Tail Lead: 0.6?mm Copper Wire
  • Approvals: UL CSA
  • Packing: 2500 or 5000 Tape/Reel

  • Back To The Top


    MDTU (51S): Slow Blow Glass Tube Fuses
  • 5?x 20 mm
  • Ampere Rating: 32 mA to 8A
  • Voltage Rating: 250 V and less
  • Electrical characteristics:
  • 135% - 1 Hour, Minimum
  • 200% - 5 seconds ~ 2 Minutes
  • Approvals: UL CSA

  • Back To The Top


    MDPU (52S): Slow Blow Glass Tube Fuses With Pig-Tail
  • 5?x 20 mm
  • Ampere Rating: 32 mA to 8A
  • Voltage Rating: 250 V and less
  • Electrical characteristics:
  • 135% - 1 Hour, Minimum
  • 200% - 5 seconds ~ 2 Minutes
  • Pig-Tail Lead: 0.6?mm Copper Wire
  • Approvals: UL CSA

  • Back To The Top


    EDLU (61S): Slow Blow Glass Tube Fuses
  • 6.3?x 32 mm (1/4 x 1 1/4 inch)
  • Ampere Rating: 32 mA to 5A
  • Voltage Rating: 250 V and less
  • Electrical characteristics:
  • 135% - 1 Hour, Minimum
  • 200% - 5 seconds ~ 2 Minutes
  • Approvals: UL CSA

  • Back To The Top


    EDPU (62S): Slow Blow Glass Tube Fuses With Pig-Tail
  • 6.3?x 32 mm (1/4 x 1 1/4 inch)
  • Ampere Rating: 32 mA to 5A
  • Voltage Rating: 250 V and less
  • Electrical characteristics:
  • 135% - 1 Hour, Minimum
  • 200% - 5 seconds ~ 2 Minutes
  • Pig-Tail Lead: 0.8?mm Copper Wire
  • Approvals: UL CSA

  • Back To The Top


    EBCU (65NM): Fast Acting Ceramic Tube Fuses
  • 6.3?x 32 mm (1/4 x 1 1/4 inch)
  • Ampere Rating: 0.5A to 15A
  • Voltage Rating: 250 V and less
  • Electrical characteristics:
  • 135% - 1 Hour, Minimum
  • 200% - 2 Minutes Maximum
  • Recommend for higher interrupting ratings and voltage ratings
  • Approvals: UL, CSA, 4A And Less

  • Back To The Top


    EBDU (65TS): Slow Blow Ceramic Tube Fuses
  • 6.3?x 32 mm (1/4 x 1 1/4 inch)
  • Ampere Rating: 1 A to 15 A
  • Voltage Rating: 250 V and less
  • Electrical characteristics:
  • 135% - 1 Hour, Minimum
  • 200% - 5 seconds ~ 2 Minutes
  • Recommend for higher interrupting ratings and voltage ratings
  • Approvals: UL, CSA

  • Back To The Top


    MGCV (50F): Quick Acting Low Breaking Capacity
  • 5?x 20 mm (0.197 x 0.787 inch)
  • Ampere Rating: 32 mA to 6.3 A
  • Voltage Rating: 250 V
  • Approvals: SEMKO, VDE, BSI
  • Electrical Characteristics:
    In 1.5 In 2.1 In 2.75 In 4 In 10 In
    32 mA ~ 100 mA > 1 H < 30 min 10 ms ~ 500 ms 3 ms ~ 100 ms < 20 ms
    125 mA ~ 6.3 A > 1 H < 30 min 50 ms ~ 2 s 10 ms ~ 300 ms < 20 ms

    Back To The Top


    MDTV (50T): Time Delay Low Breaking Capacity
  • 5?x 20 mm (0.197 x 0.787 inch)
  • Ampere Rating: 32 mA to 6.3 A
  • Voltage Rating: 250 V
  • Approvals: SEMKO, VDE, BSI
  • Electrical Characteristics:
    In 1.5 In 2.1 In 2.75 In 4 In 10 In
    32 mA ~ 100 mA > 1 H < 2 min 200 ms ~ 10 s 40 ms ~ 3 s 10 ms ~ 300 ms
    125 mA ~ 6.3 A > 1 H < 2 min 600 ms ~ 10 s 150 ms ~ 3 s 20 ms ~ 300 ms

    Back To The Top


    MBCV (50CF): Quick Acting High Breaking Capacity
  • 5?x 20 mm (0.197 x 0.787 inch)
  • Ampere Rating: 250 mA to 6.3 A
  • Voltage Rating: 250 V
  • Approvals: SEMKO, VDE, BSI
  • Electrical Characteristics:
    In 1.5 In 2.1 In 2.75 In 4 In 10 In
    250 mA ~ 6.3 A > 1 H < 30 min 10 ms ~ 2 s 3 ms ~ 300 ms < 20 ms

    Back To The Top


    MBDV (50CT): Time Delay High Breaking Capacity
  • 5?x 20 mm (0.197 x 0.787 inch)
  • Ampere Rating: 1 A to 6.3 A
  • Voltage Rating: 250 V
  • Approvals: SEMKO, VDE, BSI
  • Electrical Characteristics:
    In 1.5 In 2.1 In 2.75 In 4 In 10 In
    1 A ~ 3.15 A > 1 H < 30 min 1 s ~ 80 s 95 ms ~ 5 s 10 ms ~ 100 ms
    4 A ~ 6.3 A > 1 H < 30 min 1 s ~ 80 s 150 ms ~ 5 s 20 ms ~ 100 ms

    Back To The Top